According to DIN VDE 0100 part 710, if the voltage over one or more external cables providing the general power supply to a hospital falls to less than 90% of the nominal grid voltage for a period of more than 0.5s, the power supply must be switched for safety. Looking in the direction of energy flow, this switching has to take place at the main distribution board level, behind the feed transformers and power sources. To ensure safety, it has to guarantee that the electrical systems can be connected within 15s to a secure power source providing energy for 24 hours. Reduction of the operational period from 24 hours to 3 is only permissible if the medical treatment and inspection of patients can be safely ended within this period and the hospital evacuated.

Summary

Only proper project planning and quality-assured measurement prevent nasty surprises. The required measurement technology has to fulfil diverse requirements. Voltages, currents, power and frequency must be recorded at a high resolution of 10 ms. An average measured over 200ms or one second would not be able to detect these network fluctuations. Deviations from the sinusoidal wave and voltage transients can be recorded using oscilloscopes. Using various trigger options such as a sine envelope curve trigger can provide even more information on the fault.

Our Range for Problem-Solving

The mobile network analyzers by A. Eberle GmbH & Co. KG, Nuremberg, fulfil all these requirements. These record and evaluate over 2,200 measurement values in parallel. These measurement devices are particularly suitable for mobile use thanks to their robust design and simple means of operation. Built-in network analyzers and fault recorders are perfectly suited for permanent monitoring at a notable network point.

Do You Need Further Information?

Feel Free to Contact Us!


Contact

News From the Product Groups

Power Quality | – News

General Knowledge

Voltage Measurement Can Improve the Quality of Supply

A short study by EWI and Fraunhofer IEG shows that mandatory voltage measurements and stricter regulation of voltage quality are necessary to ensure grid stability in Germany in light of the energy transition.

Read more

General Knowledge

Power in Multiphase Systems

This technical report highlights the special features of power transmission in three-phase systems and offers valuable insights into the optimisation and analysis of modern power grids.

Read more

Webinar

»PQMobil« Webinar: New Features/Functions for Your PQ-Box/es: Presentation of WinPQ mobil V8 & V7 legacy

Webinar recording from 2025-07-29: »PQMobil - New Features/Functions for Your PQ-Box/es: Presentation of WinPQ mobil V8 & V7 legacy«.

Read more

Blogpost

Visit From the Rudolf Diesel Technical School at A. Eberle

We were happy to welcome you, Rudolf-Diesel-Fachschule! Yesterday, we had the pleasure of welcoming two classes of future electrical engineering technicians from the Rudolf-Diesel-Fachschule Nürnberg to our company in Nuremberg.

Read more

Blogpost

TOP 100 Awards 2025: Innovation for the Energy Future

💡 As part of the TOP 100 Awards 2025, we were honored to receive a special recognition last week in Mainz – personally presented by TV host and science journalist Ranga Yogeshwar.

Read more

Blogpost

University Excursion: Pentecost Excursion of the Friedrich-Alexander-University Erlangen-Nuremberg (FAU)

As a company dedicated to innovation, education, and the energy transition, we are pleased to have once again supported the Whitsun excursion of Friedrich-Alexander University Erlangen-Nuremberg (FAU) this year.

Read more

Blogpost

Further Growth at A. Eberle

Welcome to the team! We welcome our new colleagues at A. Eberle.

Read more

Blogpost

Specialist Training on Power Quality

On 27 May 2025, everything revolved around electricity, faults and how to recognise them in a specialist training course on power quality at the Balthasar Neumann Technical Centre in Trier (BNT).

Read more

Webinar

»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids 3

Webinar recording from 2025-05-14: »PQSys - PQ-Monitoring & Feeder Current Measurement in Low-Voltage Grids - part 3«.

Read more

Webinar

»PQMobil« Webinar: Power Quality Analysis in Public & Industrial Power Grids – Part 3

Webinar recording from 2025-04-02: »PQMobil - Power Quality Analysis in Public & Industrial Power Grids – Part 3«.

Read more

Training Video

»PQMobil« Training Video 7: Measurement Data

This video is all about the measurement data. What data does the PQ-Box record and what is the best way to configure it beforehand?

Read more

Webinar

»PQSys« Webinar: Presentation: »PQI-LV« – The New PQ-Analyser for Transparency in the Low-Voltage Grid

Webinar recording from 2025-02-19: »PQSys - Presentation: »PQI-LV« - The New PQ-Analyser for Transparency in the Low-Voltage Grid«.

Read more

General Knowledge

Measuring the Voltage Drop

The voltage drop is the difference between the voltage at the beginning and end of an electrical line. In an electrical network, the voltage can be reduced by the resistance and impedance of the lines, resulting in a lower voltage reaching the consumer than was originally fed in. Find out everything about measurement and calculation in this article!

Read more

Training Video

»PQSys« Training Video 1: Presentation New Functions of Firmware V3.2 for PQI-LV, PQI-DA smart & PQI-DE

In this video, we present the new functions and extended options with firmware version 3.2 for our fixed installed power quality analysers and fault recorders PQI-LV, PQI-DA smart and PQI-DE of the PQSys product range. Find out in just three minutes how the new firmware expands the application and operating options of your A. Eberle measuring devices.

Read more

Blogpost

PQ-Box User Training in Başiskele (Turkey) With Our Partner GENETEK Enerji Sistemleri Ltd.

In August, we held a training course with our partner GENETEK Enerji Sistemleri Ltd for our portable PQ network analyzers in Turkey.

Read more

Webinar

»PQMobil« Webinar: Power Quality Analysis in Public & Industrial Power Grids – Part 2

Webinar recording from 2024-11-13: »PQMobil - Power Quality Analysis in Public & Industrial Power Grids – Part 2«.

Read more

Webinar

»EOR-3DS« & »PQSys« Webinar: Digitise and monitor local network substations for the future with »EOR-3DS« & »PQSys«

Webinar recording from 2024-10-10: »EOR-3DS« & »PQSys - Digitise and monitor local network substations for the future with »EOR-3DS« & »PQSys««.

Read more

General Knowledge

Harmonics

Harmonics are waves whose frequencies are an integer multiple higher or lower than those of the fundamental oscillations. They arise due to non-linear loads in the grid when the electrical voltage is distorted due to various influencing factors. Learn more about harmonics in this article!

Read more

Training Video

»PQMobil« Training Video 6: Presentation of WinPQ Mobile 7.1

In this video we introduce you to all the new features & functions of the latest version of the analysis software »WinPQ mobil 7.1« for our portable power quality analysers. Enjoy the video and the new possibilities with your PQ-Box from A. Eberle.

Read more

Blogpost

International Partner Week 2024 – a Look Back

Our International Partner Week 2024 - many old friends and new faces were our guests, it was a pleasure.

Read more

Training Video

»PQMobil« Training Video 5: Trigger and Fault Record Settings

Discover the best trigger settings for your »PQ-Box« to accurately record network disturbances. The video shows how to configure the half-cycle, oscilloscope, and transient recorders to reliably capture essential measurement data.

Read more

Webinar

»PQSys« Webinar: PQ-Monitoring & Feeder Current Measurement With PQSys

Webinar recording from 2024-08-06: »PQSys - PQ-Monitoring & Feeder Current Measurement with PQSys«.

Read more

General Knowledge

Voltage Monitoring

Find out everything you need to know about voltage monitoring in this article. What is voltage monitoring, why is voltage monitoring essential for both energy supply companies and industrial companies and how is it implemented in compliance with standards?

Read more

General Knowledge

What Is Load Profile Measurement/Power Measurement?

This article explains the definition and difference between load profile measurement (RLM), power measurement and measuring the standard load profile. These are important methods for accurately recording energy consumption in commercial, large industrial plant as well as in the public energy grid.

Read more

Training Video

»PQMobil« Training Video 4: Create and Configure PQ Reports With Software WinPQ Mobil

This video explains everything about creating and configuring power quality reports with »WinPQ mobil«.

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

Unser Newsletter zum Thema »LVRSys®« – Niederspannungsregelung

Möchten Sie weitere interessante Inhalte wie Fachberichte, Anwendungsbeispiele und Schulungsvideos zum Thema »LVRSys®« – Niederspannungsregelung erhalten?

Melden Sie sich hier kostenfrei an:

Vielen Dank für Ihre Anmeldung zu unserem Newsletter zum Thema »LVRSys®« – Niederspannungsregelung

Hier glangen Sie zum Download: