WinPQ 6.0 and WinPQ Lite 6.0

Major Release

power-quality-messgeräte

Harmonization of the Database of Reports and All Related Interfaces

The WinPQ V6.0 is a new major release. An update to the version transfers the existing database into a harmonized and future-proof database schema. This is a necessary and major step to ensure future-oriented developments with a high backward compatibility in future versions with many open interfaces and new user interfaces.

Furthermore, we would be happy to provide you with a corresponding service offer for the major update directly. Please do not hesitate to contact us: vertrieb@a-eberle.de

In Addition to Harmonization, Other Important and Future-Oriented Features Have Been Added:

  • IEEE519 (2014) report added / template for PQI-DE / PQI-DA smart added in WinPQ lite
  • Added performance of harmonics
  • Detection of fault direction in fault records (output before / after measuring point) via Transnostic calculation methodology for all fault records of PQI-DA smart and PQI-DE’s added
  • DRAG & DROP for measurement types in visualization added
  • Group selection of measurands / Predefined measurand groups for easy and fast evaluation and visualization
  • Full support of the PQI-DE: (1) Display of differential current (thresholds: warning and alarm) & temperature events and (2) Binary inputs
  • Email dispatch possible for messages from system status
  • Counting of EN50160 events in all reports (unbalance and long-term flicker)
  • Load characteristics via reporting
  • Update process simplified – updates are stored completely in the database for easy client updates
  • Comtrade import with mapping via measured variables DB
  • Explanations and definitions added for all PQ events
  • Suppression of range violation RMS value from PQI-DA smart / PQI-DE as active event
  • Comtrade display and import functions, especially for retrofit solutions, a simple and reliable solution for old disturbance recorders during a system changeover
  • Heatmap display of all frequency ranges from 50Hz – 150kHz (Also supports PQ-Box 300 data up to 150kHz)

You will find more information about the software in our Release Notes.

New Features for the WinPQ Lite 6.0:

  • Connection to the device is closed automatically when the user is inactive (default value = 10min)
  • Online values of the residual current measurement variables
  • Online values of binary inputs
  • Addition of prefixes of measurement units for power and energy in WinPQ lite
  • Display of status of connections for IEC61850 communication visible in device status
  • Parameterization of time settings now also directly in UTC (coordinated universal time) possible
  • French user manual has been added
  • Added ripple control group designations
  • Added summer/winter time of trigger criterion in recorder treeview
  • Calibration with SSH

Security-Related Updates and Features:

  • [WinPQ lite] Update the components of SSH communication
  • [WinPQ lite] support setup and beat drive RADIUS protocol with PQI-DA smart and -DE
  • New component for encrypted database communication (client / server) with TLS 1.2 (only with MySQL database)
  • New SSH module for improved secure connection and communication with PQ devices
  • IMPORTANT: Hashes of the fingerprints of the devices must be reconfirmed in the online data!

The A. Eberle Blog

Our latest articles

TOP 100 Awards 2025: Innovation for the Energy Future

💡 As part of the TOP 100 Awards 2025, we were honored to receive a special recognition last week in Mainz – personally presented by TV host and science journalist Ranga Yogeshwar.

Read more

Visit From the Rudolf Diesel Technical School at A. Eberle

We were happy to welcome you, Rudolf-Diesel-Fachschule! Yesterday, we had the pleasure of welcoming two classes of future electrical engineering technicians from the Rudolf-Diesel-Fachschule Nürnberg to our company in Nuremberg.

Read more

University Excursion: Pentecost Excursion of the Friedrich-Alexander-University Erlangen-Nuremberg (FAU)

As a company dedicated to innovation, education, and the energy transition, we are pleased to have once again supported the Whitsun excursion of Friedrich-Alexander University Erlangen-Nuremberg (FAU) this year.

Read more

Further Growth at A. Eberle

Welcome to the team! We welcome our new colleagues at A. Eberle.

Read more

Specialist Training on Power Quality

On 27 May 2025, everything revolved around electricity, faults and how to recognise them in a specialist training course on power quality at the Balthasar Neumann Technical Centre in Trier (BNT).

Read more

Visit From the Erlangen Technical School at A. Eberle

On 22 May 2025, A. Eberle welcomed two classes from the technical school of the city of Erlangen - true to the motto: From theory to practice.

Read more

Contact request:



* Mandatory

Your data is being processed

a-eberle kontakt newsletter ×

Unser Newsletter zum Thema »LVRSys®« – Niederspannungsregelung

Möchten Sie weitere interessante Inhalte wie Fachberichte, Anwendungsbeispiele und Schulungsvideos zum Thema »LVRSys®« – Niederspannungsregelung erhalten?

Melden Sie sich hier kostenfrei an:

Vielen Dank für Ihre Anmeldung zu unserem Newsletter zum Thema »LVRSys®« – Niederspannungsregelung

Hier glangen Sie zum Download: